  • Load-side power
  • Liên hệ
  • 1140

Load-side power component

Tùy chọn bộ lọc ngõ ra Biến tần sẽ lắp đặt sau biến tần, dùng để gia tăng khoảng cách giữa mottor và biến tần (Chi tiết khoảng cách xem thêm trong catalog), giúp điện áp ngõ ra được trơn tru hơn.

Có 4 lựa chọn sau cho lọc ngõ ra G130, mã hàng căn cứ vào công suất Biến tần.

 

1.Motor reactors

Motor reactors reduce the voltage load on the motor windings by reducing the voltage gradients at the motor terminals that occur during converter operation. At the same time, the capacitive charge/discharge currents that place an additional load on the

converter output when long motor cables are used, are reduced. The maximum permissible output frequency when a motor reactor is used is 150 Hz.

The motor reactor must be installed as close as possible to the Power Module.

Power Module Type rating of the Power Module at 400 V, 500 V or 690 V Motor reactor
380 ...480 V 3 AC kW Article No.
6SL3310-1GE32-1AA3 110 6SL3000-2BE32-1AA0
6SL3310-1GE32-6AA3 132 6SL3000-2BE32-6AA0
6SL3310-1GE33-1AA3 160 6SL3600-2BE33-2AA0
6SL3310-1GE33-8AA3 200 6SL3000-2BE33-8AA0
6SL3310-1GE35-0AA3 250 6 L3000-2BE35-0AA0
6SL3310-1GE36-1AA3 315 6SL3000-2AE36-1AA0
6SL3310-1GE37-5AA3 400 6SL3000-2AE38-4AA0
6SL3310-1GE38-4AA3 450  
6SL3310-1GE41-0AA3 560 6S L3000-2AE41-0AA0
500 ...600 V 3 AC    
6SL3310-1GF31-8AA3 110 6SL3000-2AH31-8AA0
6SL3310-1GF32-2AA3 132 6SL3000-2AH32-4AA0
6SL3310-1GF32-6AA3 160 6SL3000-2AH32-6AA0
6SL3310-1GF33-3AA3 200 6SL3000-2AH33-6AA0
6SL3310-1GF34-1AA3 250 6SL3000-2AH34-5AA0
6SL3310-1GF34-7AA3 315 6SL3000-2AH34-7AA0
6SL3310-1GF35-8AA3 400 6SL3000-2AH35-8AA0
6SL3310-1GF37-4AA3 500 6SL3000-2AH38-1AA0
6SL3310-1GF3B-1AA3 560  
660... 690 V3 AC    
6SL3310-1GH28-5AA3 75 6SL3000-2AH31-0AA0
6SL3310-1GH31-0AA3 90  
6SL3310-1GH31-2AA3 110 6SL3000-2AH31-5AA0
6SL3310-1GH31-5AA3 132  
6SL3310-1GH31-8AA3 160 6SL3000-2AH31-8AA0
6SL3310-1GH32-2AA3 200 6SL3000-2AH32-4AA0
6SL3310-1GFI32-6AA3 250 6SL3000-2AH32-6AA0
6SL3310-1GH33-3AA3 315 6SL3000-2AH33-6AA0
6SL3310-1GH34-1AA3 400 6SL3000-2AH34-5AA0
6SL3310-1GH34-7AA3 450 6SL3000-2AH 34-7AA0
6SL3310-1GH35-8AA3 560 6SL3000-2AH35-8AA0
6SL3310-1GH37-4AA3 710 6SL3000-2AH38-1AA0
6SL3310-1GH38-1AA3 800  

 

2.dv/dt filter.plus VPL

dv/dt filter plus VPL (Voltage Peak Limiter) limit the voltage rateof-rise dv/dt to values < 500 V/μs and the typical voltage peaks to the following values in accordance with the limit value curve according to IEC/TS 60034-17: 2006:

• < 1000 V at Uline < 575 V

• < 1250 V at 660 V < Uline < 690 V

Standard motors with standard insulation and without insulated bearings with a supply voltage of up to 690 V can be used for converter operation if a dv/dt filter plus VPL is used.

dv/dt filters plus VPL are designed for the following maximum motor cable lengths:

• Shielded cables: 300 m (e.g. Protodur NYCWY)

• Unshielded cables: 450 m (e.g. Protodur NYY)

For shorter cable lengths (100 m shielded, 150 m unshielded), refer to dv/dt filter compact plus VPL.

Notice: The max. permissible cable length between the dv/dt filter and Power Module is 5 m.

Design: The dv/dt filter plus VPL consists of two components, which are also supplied as separate mechanical units:

• dv/dt reactor

• Voltage limiting network, which cuts-off the voltage peaks and feeds the energy back to the DC link.

Power Module Type rating of the Power Module at 400 V, 500 V or 690 V kW dv/dt filter plus VPL 
380 ...480 V 3 AC kW Article No.
6SL3310-1GE32-1AA3 110 6SL3000-2DE32-6AA0
6SL3310-1GE32-6AA3 132  
6SL3310-1GE33-1AA3 160 6SL3000-2DE35-0AA0
6SL3310-1GE33-8AA3 200  
6SL3310-1GE35-0AA3 250  
6SL3310-1GE36-1AA3 315 6SL3000-2DE38-4AA0
6SL3310-1GE37-5AA3 400  
6SL3310-1GE38-4AA3 450  
6SL3310-1GE41-0AA3 560 6SL3000-2DE41-4AA0
500 ...600 V 3 AC    
6SL3310-1GF31-8AA3 110 6SL3000-2DH32-2AA0
6SL3310-1GF32-2AA3 132  
6SL3310-1GF32-6AA3 160 6SL3000-2DH33-3AA0
6SL3310-1GF33-3AA3 200  
6SL3310-1GF34-1AA3 250 6SL3000-2DH34-1AA0
6SL3310-1GF34-7AA3 315 6SL3000-2DH35-8AA0
6SL3310-1GF35-8AA3 400  
6SL3310-1GF37-4AA3 500 6SL3000-2DH38-1AA0
6SL3310-1GF3B-1AA3 560  
660... 690 V3 AC    
6SL3310-1GH28-5AA3 75 6SL3000-2DH31-0AA0
6SL3310-1GH31-0AA3 90  
6SL3310-1GH31-2AA3 110 6SL3000-2DH31-5AA0
6SL3310-1GH31-5AA3 132  
6SL3310-1GH31-8AA3 160 6SL3000-2DH32-2AA0
6SL3310-1GH32-2AA3 200  
6SL3310-1GFI32-6AA3 250 6SL3000-2DH33-3AA0
6SL3310-1GH33-3AA3 315  
6SL3310-1GH34-1AA3 400 6SL3000-2DH34-1AA0
6SL3310-1GH34-7AA3 450 6SL3000-2DH35-8AA0
6SL3310-1GH35-8AA3 560  
6SL3310-1GH37-4AA3 710 6SL3000-2DH38-1AA0
6SL3310-1GH38-1AA3 800  

 

3.dv/dt compact plus VPL.

dv/dt filters compact plus VPL (Voltage Peak Limiter) limit the voltage rate-of-rise dv/dt to values of < 1600 V/μs and the typical voltage peaks to the following values in accordance with the limit value curve A according to IEC 60034-25: 2007:

• < 1150 V at U line < 575 V

• < 1400 V at 660 V < U line < 690 V

Standard motors with standard insulation and without insulated bearings with a supply voltage of up to 690 V can be used for converter operation if a dv/dt filter compact plus VPL is used.

dv/dt filters compact plus VPL are designed for the following maximum motor cable lengths:

• Shielded cables: 100 m (e.g. Protodur NYCWY)

• Unshielded cables: 150 m (e.g. Protodur NYY)

For longer cable lengths (> 100 m shielded, > 150 m unshielded) refer to dv/dt filter plus VPL.

Notice:

• The max. permissible cable length between the dv/dt filter and

Power Module is 5 m.

• Operation with output frequencies < 10 Hz is permissible for

max. 5 min.

Design : The dv/dt filter compact plus VPL consists of two components,

which are supplied together as a compact mechanical unit:

• dv/dt reactor

• Voltage limiting network, which cuts-off the voltage peaks and feeds the energy back to the DC link.

Power Module Type rating of the Power Module at 400 V, 500 V or 690 V kW dv/dt filter compact plus VPL
380 ...480 V 3 AC kW Article No.
6SL3310-1GE32-1AA3 110 6SL3000-2DE32-6EA0
6SL3310-1GE32-6AA3 132  
6SL3310-1GE33-1AA3 160 6SL3000-2DE35-0EA0
6SL3310-1GE33-8AA3 200  
6SL3310-1GE35-0AA3 250  
6SL3310-1GE36-1AA3 315 6SL3000-2DE38-4EA0
6SL3310-1GE37-5AA3 400  
6SL3310-1GE38-4AA3 450  
6SL3310-1GE41-0AA3 560 6SL3000-2DE41-4EA0
500 ...600 V 3 AC    
6SL3310-1GF31-8AA3 110 6SL3000-2DG32-2EA0
6SL3310-1GF32-2AA3 132  
6SL3310-1GF32-6AA3 160 6SL3000-2DG33-3EA0
6SL3310-1GF33-3AA3 200  
6SL3310-1GF34-1AA3 250 6SL3000-2DG34-1EA0
6SL3310-1GF34-7AA3 315 6SL3000-2DG35-8EA0
6SL3310-1GF35-8AA3 400  
6SL3310-1GF37-4AA3 500 6SL3000-2DG38-1EA0
6SL3310-1GF3B-1AA3 560  
660... 690 V3 AC    
6SL3310-1GH28-5AA3 75 6SL3000-2DG31-0EA0
6SL3310-1GH31-0AA3 90  
6SL3310-1GH31-2AA3 110 6SL3000-2DG31-5EA0
6SL3310-1GH31-5AA3 132  
6SL3310-1GH31-8AA3 160 6SL3000-2DG32-2EA0
6SL3310-1GH32-2AA3 200  
6SL3310-1GFI32-6AA3 250 6SL3000-2DG33-3EA0
6SL3310-1GH33-3AA3 315  
6SL3310-1GH34-1AA3 400 6SL3000-2DG34-1EA0
6SL3310-1GH34-7AA3 450 6SL3000-2DG35-8EA0
6SL3310-1GH35-8AA3 560  
6SL3310-1GH37-4AA3 710 6SL3000-2DG38-1EA0
6SL3310-1GH38-1AA3 800  

 

4. Sin-wave filter.

Sine-wave filters are available in the voltage range 380 V to 480 V up to a type rating of 250 kW, and in the voltage range 500 V to 600 V up to a type rating of 132 kW.

The sine-wave filter at the converter output supplies almost perfect sinusoidal voltages on the motor so that standard motors can be used without special cables or power derating. Standard cables can be used.

Note the following when a sine-wave filter is used:

• The output frequency is limited to max. 150 Hz (at 380 to 480 V) and 115 Hz (at 500 to 600 V).

• The maximum output voltage is limited to approx. 85% of the input voltage.

• Maximum permissible motor cable lengths:

- Unshielded cable: 450 m

- Shielded cable: 300 m

• During commissioning, the pulse frequency is increased to double the factory setting. This induces current derating, which must be applied to the built-in units' rated currents listed in the technical specifications.

Note: The reduced voltage at the motor terminals compared to the rated motor voltage means that the motor reaches the field weakening range earlier.

The sine-wave filter may be operated only when the motor is connected; sine-wave filters are not no-load-proof!

Power Module Type rating of the Power Module at 400 V, 500 V or 690 V kW
Sine-wave filter
 
380 ...480 V 3 AC kW Article No.
6SL3310-1GE32-1AA3 110 6SL3000-2CE32-3AA0
6SL3310-1GE32-6AA3 132  
6SL3310-1GE33-1AA3 160 6SL3000-2CE32-8AA0
6SL3310-1GE33-8AA3 200 6SL3000-2CE33-3AA0
6SL3310-1GE35-0AA3 250 6SL3000-2CE34-1AA0
500 ...600 V 3 AC    
6SL3310-1GF31-8AA3 110 6SL3000-2CF31-7AA
6SL3310-1GF32-2AA3 132  

 